Common Meter Reading Instrument - Windows

Analogics has developed a state of the art Windows based rugged Hand Held Computer, ATLAS to meet the end to end field requirement of Meter Reading and Field data Analysis. The ATLAS works as a conventional DOS based CMRI with CBIP compliance and also works as latest Windows based CMRI with DLMS Software tools to read any DLMS Meter.

Since the ATLAS is close to a conventional PC architecture, any Windows based legacy softwares like Smart 2K, Wincom etc.., also can be executed in the field for field data analysis.

.


Salient Features:
  • Compact
  • Rugged
  • Low Cost
  • Light Weight
  • User Programmable



Features
  • X.86 Series 32 BIt Pentium class Processor (1.0 GHz)
  • LCD TFT Display with Touch Panel
  • 45 Key Elastomeric keypad
  • Li-Ion / Li Polymer rechargeable 2600 mAh Battery
  • Compact – Lightweight – Rugged
  • Shock Vibration and Dust resistant ( IP-65)
SPECIFICATIONS OF CMRI
Processor and OS X.86 Series 32 Bit Pentium class Processor, OS supports
Windows/DOS/Linux or higher
Memory 1 GB Expandable to 2GB
Processor Clock rate 1.0 GHz or higher
Data Ports RS232, USB 2.0 / Blue Tooth
Power Rechargeable Li-Ion / Li Polymer Battery 2600 mAh / Capacity
External adaptor 230V AC, 1A
Display 4.0” TFT Display with Touch Panel
Keypad 45 keys Elastomeric keypad
Indications Charge LED / Low Battery (Bi-colour)
Battery Power
management
Auto Power OFF, Battery status Display
Operating Temperature  Temperature (0°C – 50° C)
5 – 95% RH (Non condensing)

 

WHAT IS DOS Based Hand Held Computer ?
  • A DOS based, Battery operated, Intelligent Hand Held Terminal used for Reading (data Collection) Trivector Energy Meters of Different makes
What are specifications of DOS BASED HAND HELD COMPUTER ?
  • 16 x 24 char, LCD with EL-Backlight
  • CGA compatible 192x128 pixel graphical display with virtual PC screen
  • PC compatible 45 keys Keypad
  • Two high speed communication ports
  • 20-year Calendar with built-in RTC with lithium battery backup Built-in 1.55 Ahr rechargeable NiMH Battery
What is the Memory Structure in DOS BASED HAND HELD COMPUTER?
  • 384 K Flash BIOS
  • 2MB system RAM memory, 640K reserved for DOS, balance reserved for execution of user Programs & Graphics
  • 2 MB Flash memory used for loading the common meter reading programs (like M/s. Secure, L & T, ABB, Duke Arnics etc.,)
  • 2MB / 4MB / 6MB static RAM memory is used to store meter data of various makes
Does the DOS can be upgraded by user ?
  • Yes, user can upgrade the DOS through serial port
What Version of DOS can be loaded in to DOS BASED HAND HELD COMPUTER ?
  • Any Latest version of DOS can be loaded by user i.e., ver 6.11 or higher
What are Accessories supplied with Each DOS BASED HAND HELD COMPUTER ?
  • Battery Charger
  • Communication Cables (COM 1 & COM 2)
  • User Manual
  • Carrying case
  • Floppy / CD (Containing System and utility files)
What is charging time of DOS BASED HAND HELD COMPUTER ?
  • DOS BASED HAND HELD COMPUTER will be supplied with intelligent, SMPS based chargers with temperature, time and voltage sensors. This will take 2 Hrs. 40 Min. for one full charge when battery is in full discharged condition. The charger works from 85 V to 265 V, 0 to 400 Hz frequency
How many hours will DOS BASED HAND HELD COMPUTER work continuously with full charged battery ?
  • It works continuously for 8 Hrs. (without backlit)
How many meter software’s can be loaded into DOS BASED HAND HELD COMPUTER?
  • On an average, 4 to 5 meter softwares (like M/s. Secure, L & T, Duke Arnics, ABB, Data Pro etc.,) can be loaded into one DOS BASED HAND HELD COMPUTER
How to analyze the Reading taken from Meter ?
  • Data (Reading) taken from the meter is transferred to PC i.e., Base computer, using the software of specific meter. Using these BCs we can view the Instantaneous current, voltage, billing data, tamper data, load survey graph, phasor diagrams etc.
Why Graphics Display ? Why not text display like 4 line by 20 characters ?
  • Graphics Display is the latest display technology, facilitates to display load survey graphs, phasor diagrams etc., in the field itself to get better control over the vital field data
  • Wide Screen Graphics Display will enable user friendly menus with features close to normal PCs. Lowest, small format, text displays will not provide all those features

Datasheet
  • Common Meter Reading Instrument - Windows

Download

View